Daikin ACEF 3AV1-(C)(H) Specifications Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
2.0 3.0
AKZ569
ーT
*9
ーCーB
ーCーBーH
AKZ909
5.0/5.6 8.0/9.0
φ455、100Wφ400、100W
0.75kW×4P
0.75kW×4P
0.7kW×4P
5∼50
5∼45
5∼50
1.4∼200(ISO VG2∼32)
c1 1/4
c1 1/4
c1 1/4Rc 1
DC12/24V
30/36
0.6
2.50kW/8.4A
2.57kW/8.1A
3.00kW/8.9A
2.22kW/7.7A
2.30kW/7.6A
2.30kW/7.3A
1.02 1.48
65 67
IP2X
ーT
*9
ーH
15−−
0.7kW×4P
1375×470×580
1110×470×560
1410×470×560 1360×470×590 1485×560×700
1220×560×680
1520×560×680 1470×560×659
c1 1/4 c1 1/4Rc 1
11582
20
97100 145
132 122 175
−50 −70
4.0kVA
*3 *3
4.25kW/13.6A
4.30kW/13.5A
4.28kW/13.0A
2
6.0kVA
ーー
3ーー
40
30
20
10
0
01020304050
50
*10
*10
0.75kW×4P
AKZ569
AKZ909
Range of use
6
AKZ 9 SERIES
Specifications and range of use
Oil Cooling Unit horsepower(HP)
Cooling capacity(50/60Hz)
*1
kW
kW
200V 50Hz
200V 60Hz
220V 60Hz
mm
L/min
MPa
K
Discharge side
Suction side
mm
2
/s
kg
Heater
Supply power
*2
Transformer capacity
Exterior color
Outside dimensionsH×W×D
Compressor(Totally enclosed DC swing type)
Evaporator
Condenser
Propeller fan
Refrigerant control
Transport vibration performance
*7
Refrigerant(New refrigerant: R410A)
*5
Filling amount
Usable oil
Noise value(Value measured at 1m high in front,
value equivalent as measured in anechoic chamber)
Protection equipment
Fixed
type
Standard
Object to be controlled
Synchronization
range
Object to be controlled
Range
Oil
pump
Motor
Theoretical discharge rate
Open pressure
Max. power consumption
Max. consumption current
Main circuit
*3
Operating circuit
Circuit voltage
Model name
Operating
range
Product external
pressure loss
Oil viscosity
Inlet oil temperature
Room temperature
Oil inlet
Oil drain
Oil outlet
Connecting tube
kg
dB(A)
Mass
A
Molded-case circuit breaker(Rated current)
L
A
Oil tank(Capacity)
Temperature
adjust
(Selectable)
Syn-
chroni-
zation
type
Motor
Stan
dard
Stan
dard
3-Phase 200/200220V 50/60z
Equivalent to 1.5kW Equivalent to 2.2kW
3-Phase 200/200220V 50/60z 3-Phase 200/200220V 50/60z
Cross-fin coil type
Room temperature or machine temperature
*4
(Set to “Room temperature: Mode 3” by default)
Inlet oil temperature or outlet oil temperature(Set to “Inlet oil temperature” by default)
9.9∼9.9 against the standard temperature(Set at 0.0 by default)
Inlet oil temperature or outlet oil temperature
Compressor revolutions by inverter Opening of electric expansion valve
A set of overcurrent relay(motor for pump), reverse-phase protection equipment, restart prevention timer, low room-temperature protection thermostat, high
room-temperature protection thermostat, low oil-temperature protection thermostat, relief valve for pump, discharge tube temperature thermostat, condenser
temperature thermostat, refrigerant leak detector, and inverter protection equipment. High-pressure switchC type only), compressor protection thermostat
C type only), overheat prevention temperature thermostatH type only), boil-dry protection switchH type only), no-fuse breaker (B type only)
0.5MPa or less
30.7kPa or less
Lubricant, hydraulic oil of mineral oil(Not usable for hydraulic oil of ester phosphate, water, water-soluble liquid, drugs, food products, fuel, cutting liquid, grinding liquid, etc.)
c1/4(Plugged)
Up down 14.7m/S
2
×2.5 hr(7.5∼100Hz sweep / 5 min.)
15(Required for types other than B type) 20(Required for types other than B type)
Note)1. The mark ◎ shows the standard point.
2. Be sure to use the unit at the range
of use specified in     .
(The use outside the use range may cause unit failure.)
Room temperature
Inlet temperature(℃)
Different voltage
specifications
*
3
Ivory white
Different voltage
specifications
*
3
Molded-case circuit
breaker(Rated current)
Items to be prepared
by customer
*
8
Ingress protection
*6
Brazed plate type
Refer to Page 5 for explanatory notes.