Daikin FTXD Service Manual

Browse online or download Service Manual for Remote controls Daikin FTXD. Daikin FTXD Technical data User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 29
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
FTK/FTX(D)-JA/H/J
Wall Mounted
Inverter Controlled Unit
technical data
Split
Sky Air
air conditioning systems
Page view 0
1 2 3 4 5 6 ... 28 29

Summary of Contents

Page 1 - Inverter Controlled Unit

FTK/FTX(D)-JA/H/JWall MountedInverter Controlled Unittechnical data SplitSky Airair conditioning systems

Page 2 - Split - Sky Air

4Piping diagramsFTK25-35JAFTX25-35JA4D019960DIndoor unitHeat exchangerCross flow fanFan motorField pipingAFTK25-FTX25-9.5FTK35-FTX35-12.7Field pipingT

Page 3 - TABLE OF CONTENTS

FTXD50∼71JThermistor on inlet pipe4D024820AIndoor unitHeat exchangerCross flow fanFan motorField pipingNote:1. Gas pipe specificationABFTXD50 12.7 6.4

Page 4 - 2!00 3 6

5Wiring diagramsFTK25-35JA3D020027FgField wiringOutdoorIndoorInfrared remotecontrolRProtective earthC70 Running capacitorFU FuseH1P∼H3P Pilot lampM1F

Page 5 - Specifications

FTX25-35JA3D020026FgField wiringOutdoorIndoorInfrared remotecontrolRProtective earthC70 Running capacitorFU FuseH1P∼H3P Pilot lampM1F Fan motorM1S Swi

Page 6

6Sound level6-1Sound level dataCooling onlyModelSound pressure levelSound power level (H)230VMeasuring location50HzHLFTK25JAV1NB 38 26 54FTK35JAV1NB 3

Page 7

6Sound level6-2Sound pressure spectrumOctave band sound pressure leveldB:(0dB = 0.0002 µ bar)Octave band sound pressure leveldB:(0dB = 0.0002 µ bar)Oc

Page 8 - Dimensional drawings

Octave band sound pressure leveldB:(0dB = 0.0002 µ bar)Octave band sound pressure leveldB:(0dB = 0.0002 µ bar)Octave band center frequency (Hz)Octave

Page 9

Octave band sound pressure leveldB:(0dB = 0.0002 µ bar)Octave band sound pressure leveldB:(0dB = 0.0002 µ bar)Octave band center frequency (Hz)Octave

Page 10 - Piping diagrams

Octave band sound pressure leveldB:(0dB = 0.0002 µ bar)Octave band sound pressure leveldB:(0dB = 0.0002 µ bar)Octave band center frequency (Hz)Octave

Page 11 - FTXD71 15.9 9.5

7Air flow patternsFTX35JA (Cooling Discharge Angle: 0°)Cooling - air velocity distributionFTX35JA (Heating Discharge Angle: 0°)Cooling - air temperatu

Page 12 - Wiring diagrams

Split - Sky AirEE DE02-1/1A • 10/2002Prepared in Belgium by Goekint GraphicsZandvoordestraat 300B - 8400 Ostend BelgiumInternet: http://www.daikineuro

Page 13

FTX35JA (Cooling Discharge Angle: 45°)Cooling - air velocity distributionFTX35JA (Heating Discharge Angle: 45°)Cooling - air temperature distributionQ

Page 14 - Sound level

FTXD60J (Cooling Discharge Angle: 15°)Cooling - air velocity distributionFTXD60J (Heating Discharge Angle: 15°)Cooling - air temperature distributionQ

Page 15

FTXD60J (Cooling Discharge Angle: 40°)Cooling - air velocity distributionFTXD60J (Heating Discharge Angle: 40°)Cooling - air temperature distributionQ

Page 16

8Accessories8-1Standard accessoriesjAMounting plate 1jERemote control holder z11jJInsulation tape (25/35 class only) 1jBMounting plate fixing screwM4

Page 17

9Control systems9-1Infrared remote controlFTK25-35JAV1NBDisplayOFF TIMER buttonON TIMER buttonMODE selector buttonSWING buttonTransmitterOn/Off button

Page 18

FTK50-60HV1NBDisplayOFF TIMER buttonON TIMER buttonMODE selector buttonSWING buttonTransmitterOn/Off buttonTEMPERATURE/TIMEadjustment buttonsCLOCK but

Page 19 - Air flow patterns

FTX25-35JAV1NBDisplayOFF TIMER buttonON TIMER buttonMODE selector buttonSWING buttonTransmitterOn/Off buttonTEMPERATURE/TIME adjustmentbuttonsCLOCK bu

Page 20

FTXD50,60,71JV1BDisplayOFF TIMER buttonON TIMER buttonMODE selector buttonSWING buttonTransmitterOn/Off buttonTEMPERATURE/TIME adjustment buttonsCLOCK

Page 21

10Centre of gravityFTK25-35JAV1NBFTX25-35JAV1NBFTXD50-60-71JV1B4D020686D4D027652•Wall Mounted Inverter Controlled Unit •R-22 •FTK/FTX-JA/FTX-H/FTXD-J2

Page 22

11InstallationjAMounting plateThe mounting plate should beinstalled on a wall which cansupport the weight of the indoorunit.Mounting plateIndoor/outdo

Page 23 - Accessories

TABLE OF CONTENTSFTK/FTX(D)-JA/H/J1 Features ... 22 Specifications...

Page 24 - Control systems

1Features+ Lightweight and compact+ Extremely quiet in operation both indoors and outdoors+ A silent button on the remote control lowers the operation

Page 25

2SpecificationsNOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FTK25JAV1NB FTK35JAV1NB FTK50HV1NB FTK60HV1NBNOMINAL INPUT Cooling

Page 26

NOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FTX25JAV1NB FTX35JAV1NB FTXD50JV1B FTXD60JV1B FTXD71JV1BNOMINAL INPUT Cooling kW

Page 27 - Infrared remote control

ELECTRICAL SPECIFICATIONSFor indoor units only: FTK25JAV1NB FTK35JAV1NB FTK50HV1NB FTK60HV1NBCURRENT Nominal running currentcoolingA 0.18 0.18 0.5 0.6

Page 28 - Centre of gravity

3Dimensional drawingsFTK25-35JAFTK25 J 9.5CutFTK35 J 12.7Cutunit (mm)3D019915-CLeftRearRightThe mark (Y) shows piping directionIntelligent eye sensori

Page 29 - Installation

FTX25-35JAFTX25 J 9.5CutFTX35 J 12.7Cutunit (mm)3D019914DLeftRearRightThe mark (Y) shows piping directionIntelligent eye sensorindicator lampSignal re